{"id":11024,"date":"2022-07-05T07:25:37","date_gmt":"2022-07-04T21:25:37","guid":{"rendered":"https:\/\/nsrd.info\/blog\/?p=11024"},"modified":"2022-07-08T14:38:41","modified_gmt":"2022-07-08T04:38:41","slug":"powerprotect-data-manager-19-11-whats-new-and-updating","status":"publish","type":"post","link":"https:\/\/nsrd.info\/blog\/2022\/07\/05\/powerprotect-data-manager-19-11-whats-new-and-updating\/","title":{"rendered":"PowerProtect Data Manager 19.11 \u2013 What&#8217;s New, and Updating"},"content":{"rendered":"\n<p>At the end of June, PowerProtect Data Manager 19.11 was released. In this post, I&#8217;ll take you through what&#8217;s new, and then also step through the update process.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">What&#8217;s new in PowerProtect Data Manager 19.11?<\/h2>\n\n\n\n<p>You can find all the documentation and downloads for Data Manager 19.11 at the <strong><a href=\"https:\/\/www.dell.com\/support\/home\/en-au\/product-support\/product\/enterprise-copy-data-management\/overview\" target=\"_blank\" rel=\"noreferrer noopener\">official support site, here<\/a><\/strong>. I&#8217;ll run through and summarise the key changes from the release notes, below.<\/p>\n\n\n\n<ul class=\"wp-block-list\"><li><strong>Oracle<\/strong> support:<ul><li>The UI now supports centralized Oracle restore\/recovery for Oracle systems that have been backed up via protection policies. This covers: full database restore, archive log restore, and disaster recovery of a database including the control files and spfile.<\/li><li>Support for Oracle 21c RMAN features.<\/li><\/ul><\/li><li>Improved logic for <strong>Microsoft SQL<\/strong> Server backups:<ul><li>If transaction log backup chains span full backups, the transaction log backups and full backups can run concurrently, without promoting the transaction log backups to a full backup.<\/li><\/ul><\/li><li><strong>Agent <\/strong>updates:<ul><li>Starting with Data Manager 19.11, you can perform push updates from the UI of application agents. The application agents will need to be on at least 19.10 to support this.<\/li><\/ul><\/li><li><strong>Kubernetes <\/strong>support:<ul><li>In-flight encryption for k8s backups is now supported.<\/li><li>Support for protecting k8s PVCs in different PowerScale access zones.<\/li><li>Support for volume-group snapshotting for k8s PVCs using the PowerFlex CSI driver.<\/li><\/ul><\/li><li><strong>Logging<\/strong>:<ul><li>Syslog support for auditing, monitoring and troubleshooting &#8211; this is now available under the Settings &gt; Log menu.<\/li><\/ul><\/li><li><strong>Protection <\/strong>updates:<ul><li>Replication can now be configured to trigger as soon as a the backups in a policy complete.<\/li><li>You can now replicate to a different Mtree on the same Data Domain, but with a different retention period. (This is useful when you want to limit the amount of data you pull into a Cyber Vault.)<\/li><li>You can now override automated protection engine selection and choose which protection engine you wish to use for VM restores.<\/li><li>Support for self-service restores without administrative intervention.<\/li><\/ul><\/li><li><strong>Security<\/strong>:<ul><li>Support for configuration of scopes of authority for users. This lets you limit users to not only particular roles, but particular roles against specific assets, asset sources, etc.<\/li><\/ul><\/li><li><strong>Disaster recovery<\/strong>:<ul><li>Quick recovery is now supported from Smart Scale system pools.<\/li><li>Enhancements for DD Boost server DR backup and restore.<\/li><\/ul><\/li><li><strong>Table exports<\/strong>:<ul><li>If Data Manager shows you information in a tabular format, you can export it in CSV format.<\/li><\/ul><\/li><\/ul>\n\n\n\n<p>There are a bunch of changed features as well, but I&#8217;ll let you review them in the release notes (see link above).<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Updating to PowerProtect Data Manager 19.11<\/h2>\n\n\n\n<p>If you&#8217;ve connected Data Manager to Dell SupportAssist, you&#8217;ll be able to check for and retrieve the update package through the Update manager. For my lab system, I&#8217;m working in an &#8216;offline&#8217; mode where I have to transfer the update package manually. So let&#8217;s get started.<\/p>\n\n\n\n<p>First, go to <strong>Settings &gt; Software Update<\/strong>:<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><a href=\"https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00001.png\"><img loading=\"lazy\" decoding=\"async\" width=\"1873\" height=\"930\" src=\"https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00001.png\" alt=\"PowerProtect Data Manager: Invoking Software Update\" class=\"wp-image-11027\" srcset=\"https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00001.png 1873w, https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00001-300x149.png 300w, https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00001-1024x508.png 1024w, https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00001-768x381.png 768w, https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00001-1536x763.png 1536w, https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00001-1600x794.png 1600w\" sizes=\"auto, (max-width: 1873px) 100vw, 1873px\" \/><\/a><figcaption><strong><em>PowerProtect Data Manager: Invoking Software Update<\/em><\/strong><\/figcaption><\/figure>\n\n\n\n<p>Once you&#8217;re in the Software Update utility, you can either source and download the package via SupportAssist, or in my case, upload:<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><a href=\"https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00002.png\"><img loading=\"lazy\" decoding=\"async\" width=\"1154\" height=\"820\" src=\"https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00002.png\" alt=\"PowerProtect Data Manager: Click 'Upload Package'\" class=\"wp-image-11028\" srcset=\"https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00002.png 1154w, https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00002-300x213.png 300w, https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00002-1024x728.png 1024w, https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00002-768x546.png 768w\" sizes=\"auto, (max-width: 1154px) 100vw, 1154px\" \/><\/a><figcaption><strong><em>PowerProtect Data Manager: Click &#8216;Upload Package&#8217;<\/em><\/strong><\/figcaption><\/figure>\n\n\n\n<p>Once you select the package from your local hard-drive to upload, you&#8217;ll get a progress indicator as it is transferred to the server:<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><a href=\"https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00003.png\"><img loading=\"lazy\" decoding=\"async\" width=\"577\" height=\"254\" src=\"https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00003.png\" alt=\"PowerProtect Data Manager: Update package transfer progress indicator\" class=\"wp-image-11029\" srcset=\"https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00003.png 577w, https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00003-300x132.png 300w\" sizes=\"auto, (max-width: 577px) 100vw, 577px\" \/><\/a><figcaption><strong><em>PowerProtect Data Manager: Update package transfer progress indicator<\/em><\/strong><\/figcaption><\/figure>\n\n\n\n<p>When the transfer is complete, Data Manager will review the transferred package. Depending on your system speed this may take a little while to complete, so you can dismiss the update dialog and come back later if you&#8217;d like. Once the review is complete, you&#8217;ll see a status such as the following indicating the package checks out:<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><a href=\"https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00004.png\"><img loading=\"lazy\" decoding=\"async\" width=\"1153\" height=\"820\" src=\"https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00004.png\" alt=\"PowerProtect Data Manager: Update Package Ready\" class=\"wp-image-11030\" srcset=\"https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00004.png 1153w, https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00004-300x213.png 300w, https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00004-1024x728.png 1024w, https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00004-768x546.png 768w\" sizes=\"auto, (max-width: 1153px) 100vw, 1153px\" \/><\/a><figcaption><strong><em>PowerProtect Data Manager: Update Package Ready<\/em><\/strong><\/figcaption><\/figure>\n\n\n\n<p>You can click the &#8216;More Details&#8217; link to see information about the components in the update. If you do it while the package is still processing, you&#8217;ll see status information about the checks of each updatable component:<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><a href=\"https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00005.png\"><img loading=\"lazy\" decoding=\"async\" width=\"1152\" height=\"675\" src=\"https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00005.png\" alt=\"PowerProtect Data Manager: Sub Components View\" class=\"wp-image-11031\" srcset=\"https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00005.png 1152w, https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00005-300x176.png 300w, https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00005-1024x600.png 1024w, https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00005-768x450.png 768w\" sizes=\"auto, (max-width: 1152px) 100vw, 1152px\" \/><\/a><figcaption><strong><em>PowerProtect Data Manager: Sub Components View<\/em><\/strong><\/figcaption><\/figure>\n\n\n\n<p>There&#8217;s a pre-check option that you can invoke manually if you want. The same pre-check is run as the first step when you click Install Package. While pre-check is running, you&#8217;ll get a status indicator shown in the update screen:<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><a href=\"https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00007.png\"><img loading=\"lazy\" decoding=\"async\" width=\"1154\" height=\"818\" src=\"https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00007.png\" alt=\"PowerProtect Data Manager: Pre-check running\" class=\"wp-image-11033\" srcset=\"https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00007.png 1154w, https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00007-300x213.png 300w, https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00007-1024x726.png 1024w, https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00007-768x544.png 768w\" sizes=\"auto, (max-width: 1154px) 100vw, 1154px\" \/><\/a><figcaption><strong><em>PowerProtect Data Manager: Pre-check running<\/em><\/strong><\/figcaption><\/figure>\n\n\n\n<p>At the conclusion of the pre-check, you&#8217;ll be notified of anything you need to be aware of. In my instance, I run Data Manager using a bare-bones resource allocation, so I was notified that my memory was a little low, which I expected to see:<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><a href=\"https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00008.png\"><img loading=\"lazy\" decoding=\"async\" width=\"1153\" height=\"627\" src=\"https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00008.png\" alt=\"PowerProtect Data Manager: Pre-check results\" class=\"wp-image-11034\" srcset=\"https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00008.png 1153w, https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00008-300x163.png 300w, https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00008-1024x557.png 1024w, https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00008-768x418.png 768w\" sizes=\"auto, (max-width: 1153px) 100vw, 1153px\" \/><\/a><figcaption><strong><em>PowerProtect Data Manager: Pre-check results<\/em><\/strong><\/figcaption><\/figure>\n\n\n\n<p>The pre-check will also warn you of any required activities &#8212; such as taking a snapshot of the appliance before commencing the update. This is only required if the hosting vCenter for Data Manager isn&#8217;t configured in the asset sources. (If Data Manager has administrative access to the vCenter environment it is running in, it&#8217;ll handle the snapshot automatically.)<\/p>\n\n\n\n<p>Clicking Next, you&#8217;re prompted to confirm the package certificate:<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><a href=\"https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00009.png\"><img loading=\"lazy\" decoding=\"async\" width=\"1154\" height=\"624\" src=\"https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00009.png\" alt=\"PowerProtect Data Manager: Confirm certificate details\" class=\"wp-image-11036\" srcset=\"https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00009.png 1154w, https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00009-300x162.png 300w, https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00009-1024x554.png 1024w, https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00009-768x415.png 768w\" sizes=\"auto, (max-width: 1154px) 100vw, 1154px\" \/><\/a><figcaption><strong><em>PowerProtect Data Manager: Confirm certificate details<\/em><\/strong><\/figcaption><\/figure>\n\n\n\n<p>Clicking Next, you&#8217;re provided a summary of the details show so far, and given a final opportunity to either cancel the update for now, or click Finish to confirm you&#8217;re OK to proceed.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><a href=\"https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00010.png\"><img loading=\"lazy\" decoding=\"async\" width=\"1161\" height=\"632\" src=\"https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00010.png\" alt=\"PowerProtect Data Manager: Start updating?\" class=\"wp-image-11037\" srcset=\"https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00010.png 1161w, https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00010-300x163.png 300w, https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00010-1024x557.png 1024w, https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00010-768x418.png 768w\" sizes=\"auto, (max-width: 1161px) 100vw, 1161px\" \/><\/a><figcaption><strong><em>PowerProtect Data Manager: Start updating?<\/em><\/strong><\/figcaption><\/figure>\n\n\n\n<p>Once you start the update process, you&#8217;ll be redirected to a dedicated web portal for monitoring the process, since the standard UI is shutdown for the update:<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><a href=\"https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00011.png\"><img loading=\"lazy\" decoding=\"async\" width=\"1872\" height=\"929\" src=\"https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00011.png\" alt=\"PowerProtect Data Manager: Monitoring the update\" class=\"wp-image-11038\" srcset=\"https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00011.png 1872w, https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00011-300x149.png 300w, https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00011-1024x508.png 1024w, https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00011-768x381.png 768w, https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00011-1536x762.png 1536w, https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00011-1600x794.png 1600w\" sizes=\"auto, (max-width: 1872px) 100vw, 1872px\" \/><\/a><figcaption><strong><em>PowerProtect Data Manager: Monitoring the update<\/em><\/strong><\/figcaption><\/figure>\n\n\n\n<p>The update starts by running a backup of the appliance details and taking a snapshot:<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><a href=\"https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00012.png\"><img loading=\"lazy\" decoding=\"async\" width=\"774\" height=\"305\" src=\"https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00012.png\" alt=\"PowerProtect Data Manager: Taking appliance backup\" class=\"wp-image-11039\" srcset=\"https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00012.png 774w, https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00012-300x118.png 300w, https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00012-768x303.png 768w\" sizes=\"auto, (max-width: 774px) 100vw, 774px\" \/><\/a><figcaption><strong><em>PowerProtect Data Manager: Taking appliance backup<\/em><\/strong><\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full\"><a href=\"https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00013.png\"><img loading=\"lazy\" decoding=\"async\" width=\"771\" height=\"317\" src=\"https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00013.png\" alt=\"PowerProtect Data Manager: Taking update snapshot\" class=\"wp-image-11040\" srcset=\"https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00013.png 771w, https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00013-300x123.png 300w, https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00013-768x316.png 768w\" sizes=\"auto, (max-width: 771px) 100vw, 771px\" \/><\/a><figcaption><strong><em>PowerProtect Data Manager: Taking update snapshot<\/em><\/strong><\/figcaption><\/figure>\n\n\n\n<p>Once these are done, the update is fully entered into. But you&#8217;ll notice there&#8217;s an option at the bottom of the update screen to abort and rollback if you need to. How is rollback handled? That&#8217;s the power of the snapshot that&#8217;s taken before starting&#8230;<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><a href=\"https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00014.png\"><img loading=\"lazy\" decoding=\"async\" width=\"1872\" height=\"927\" src=\"https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00014.png\" alt=\"PowerProtect Data Manager: Shutting down components for update\" class=\"wp-image-11041\" srcset=\"https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00014.png 1872w, https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00014-300x149.png 300w, https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00014-1024x507.png 1024w, https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00014-768x380.png 768w, https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00014-1536x761.png 1536w, https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00014-1600x792.png 1600w\" sizes=\"auto, (max-width: 1872px) 100vw, 1872px\" \/><\/a><figcaption><strong><em>PowerProtect Data Manager: Shutting down components for update<\/em><\/strong><\/figcaption><\/figure>\n\n\n\n<p>Throughout the update process, you&#8217;ll get status indicators of what is being worked on and a view of the time remaining. Here are a few, below:<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><a href=\"https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00015.png\"><img loading=\"lazy\" decoding=\"async\" width=\"1874\" height=\"930\" src=\"https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00015.png\" alt=\"PowerProtect Data Manager: Updating RPMs\" class=\"wp-image-11042\" srcset=\"https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00015.png 1874w, https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00015-300x149.png 300w, https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00015-1024x508.png 1024w, https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00015-768x381.png 768w, https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00015-1536x762.png 1536w, https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00015-1600x794.png 1600w\" sizes=\"auto, (max-width: 1874px) 100vw, 1874px\" \/><\/a><figcaption><strong><em>PowerProtect Data Manager: Updating RPMs<\/em><\/strong><\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full\"><a href=\"https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00016.png\"><img loading=\"lazy\" decoding=\"async\" width=\"1872\" height=\"929\" src=\"https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00016.png\" alt=\"PowerProtect Data Manager: Applying security update\" class=\"wp-image-11043\" srcset=\"https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00016.png 1872w, https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00016-300x149.png 300w, https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00016-1024x508.png 1024w, https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00016-768x381.png 768w, https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00016-1536x762.png 1536w, https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00016-1600x794.png 1600w\" sizes=\"auto, (max-width: 1872px) 100vw, 1872px\" \/><\/a><figcaption><strong><em>PowerProtect Data Manager: Applying security update<\/em><\/strong><\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full\"><a href=\"https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00017.png\"><img loading=\"lazy\" decoding=\"async\" width=\"1874\" height=\"929\" src=\"https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00017.png\" alt=\"PowerProtect Data Manager: Starting components\" class=\"wp-image-11044\" srcset=\"https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00017.png 1874w, https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00017-300x149.png 300w, https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00017-1024x508.png 1024w, https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00017-768x381.png 768w, https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00017-1536x761.png 1536w, https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00017-1600x793.png 1600w\" sizes=\"auto, (max-width: 1874px) 100vw, 1874px\" \/><\/a><figcaption><strong><em>PowerProtect Data Manager: Starting components<\/em><\/strong><\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full\"><a href=\"https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00018.png\"><img loading=\"lazy\" decoding=\"async\" width=\"1873\" height=\"928\" src=\"https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00018.png\" alt=\"PowerProtect Data Manager: Data migration completed\" class=\"wp-image-11045\" srcset=\"https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00018.png 1873w, https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00018-300x149.png 300w, https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00018-1024x507.png 1024w, https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00018-768x381.png 768w, https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00018-1536x761.png 1536w, https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00018-1600x793.png 1600w\" sizes=\"auto, (max-width: 1873px) 100vw, 1873px\" \/><\/a><figcaption><strong><em>PowerProtect Data Manager: Data migration completed<\/em><\/strong><\/figcaption><\/figure>\n\n\n\n<p>Once the core system has been updated, internal data is migrated between any old to new service changes (shown above). At this point, the update process moves on to handle any deployed data movers (e.g., VMware, NAS, etc.), and helpers such as search and reporting engines.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><a href=\"https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00019.png\"><img loading=\"lazy\" decoding=\"async\" width=\"1873\" height=\"929\" src=\"https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00019.png\" alt=\"PowerProtect Data Manager: Updating external components\" class=\"wp-image-11046\" srcset=\"https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00019.png 1873w, https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00019-300x149.png 300w, https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00019-1024x508.png 1024w, https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00019-768x381.png 768w, https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00019-1536x762.png 1536w, https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00019-1600x794.png 1600w\" sizes=\"auto, (max-width: 1873px) 100vw, 1873px\" \/><\/a><figcaption><strong><em>PowerProtect Data Manager: Updating external components<\/em><\/strong><\/figcaption><\/figure>\n\n\n\n<p>Once all the external components have been updated, the update process will wrap up and return to you the login screen. When you login, you&#8217;ll get a summary of the features in the new version, which you can either allow to keep coming up on login, or dismiss until the next update:<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><a href=\"https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00020.png\"><img loading=\"lazy\" decoding=\"async\" width=\"937\" height=\"540\" src=\"https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00020.png\" alt=\"PowerProtect Data Manager: What's new screen\" class=\"wp-image-11047\" srcset=\"https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00020.png 937w, https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00020-300x173.png 300w, https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00020-768x443.png 768w\" sizes=\"auto, (max-width: 937px) 100vw, 937px\" \/><\/a><figcaption><strong><em>PowerProtect Data Manager: What&#8217;s new screen<\/em><\/strong><\/figcaption><\/figure>\n\n\n\n<p>Finally, once you&#8217;ve dismissed the What&#8217;s New screen, you&#8217;ll be back at the familiar Data Manager dashboard view:<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><a href=\"https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00021.png\"><img loading=\"lazy\" decoding=\"async\" width=\"1872\" height=\"929\" src=\"https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00021.png\" alt=\"PowerProtect Data Manager 19.11 Dashboard\" class=\"wp-image-11048\" srcset=\"https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00021.png 1872w, https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00021-300x149.png 300w, https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00021-1024x508.png 1024w, https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00021-768x381.png 768w, https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00021-1536x762.png 1536w, https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00021-1600x794.png 1600w\" sizes=\"auto, (max-width: 1872px) 100vw, 1872px\" \/><\/a><figcaption><strong><em>PowerProtect Data Manager 19.11 Dashboard<\/em><\/strong><\/figcaption><\/figure>\n\n\n\n<p>And that&#8217;s the update process!<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<p>Edit: My friend Karsten Bott has posted an excellent article that steps through the process of updating PowerProtect Data Manager using Ansible Roles and Playbooks. <strong><a href=\"https:\/\/bottkars.github.io\/Update_PPDM_Using_ansible\/\" target=\"_blank\" rel=\"noreferrer noopener\">You should check it out, here<\/a><\/strong>.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>At the end of June, PowerProtect Data Manager 19.11 was released. In this post, I&#8217;ll take you through what&#8217;s new,&hellip;<\/p>\n","protected":false},"author":1,"featured_media":11048,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"jetpack_post_was_ever_published":false,"_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_publicize_message":"","jetpack_publicize_feature_enabled":true,"jetpack_social_post_already_shared":true,"jetpack_social_options":{"image_generator_settings":{"template":"highway","default_image_id":0,"font":"","enabled":false},"version":2}},"categories":[1520],"tags":[1616,1558,1050],"class_list":["post-11024","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-powerprotect","tag-powerprotect-data-manager","tag-ppdm","tag-update"],"aioseo_notices":[],"jetpack_publicize_connections":[],"jetpack_featured_media_url":"https:\/\/nsrd.info\/blog\/wp-content\/uploads\/2022\/07\/PPDM_1911_Upgrade_00021.png","jetpack_shortlink":"https:\/\/wp.me\/pKpIN-2RO","jetpack_sharing_enabled":true,"jetpack_likes_enabled":true,"_links":{"self":[{"href":"https:\/\/nsrd.info\/blog\/wp-json\/wp\/v2\/posts\/11024","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/nsrd.info\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/nsrd.info\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/nsrd.info\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/nsrd.info\/blog\/wp-json\/wp\/v2\/comments?post=11024"}],"version-history":[{"count":5,"href":"https:\/\/nsrd.info\/blog\/wp-json\/wp\/v2\/posts\/11024\/revisions"}],"predecessor-version":[{"id":11074,"href":"https:\/\/nsrd.info\/blog\/wp-json\/wp\/v2\/posts\/11024\/revisions\/11074"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/nsrd.info\/blog\/wp-json\/wp\/v2\/media\/11048"}],"wp:attachment":[{"href":"https:\/\/nsrd.info\/blog\/wp-json\/wp\/v2\/media?parent=11024"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/nsrd.info\/blog\/wp-json\/wp\/v2\/categories?post=11024"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/nsrd.info\/blog\/wp-json\/wp\/v2\/tags?post=11024"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}